Applications
- Suitable for use and recommended for fire fighting
activities in:
- Municipal fire departments
- Industrial fire brigades
- Petrochemical fire protection
- Shipboard fire fighting
- Municipal supply lines
- Well Protection
- Heavy duty wash down
- Jetting
- Snow making
- Dewatering & slurrry applications
- Hydrant bypass
Suitable for many other applications requiring a heavy duty, high pressure
hose resistant to petroleum, chemicals, ozone attack in extreme conditions;
Non fire fighting applications "OROFLEX" hoses with similar characteristics
are also recommended
Hose Construction
Hose shall be made from 100% high tenacity synthetic
yarn circular woven and completely protected and locked-in by tough highly
resistant synthetic nitrile rubber, forming a single homogenous construction
without the use of glues or adhesives of any type. Cover incorporates a QR
square rib configuration under 4’ and
SR single rib on 4” and over to enhance abrasion resistance.
Lining Properties
- Ultimate Tensile Strength:
Tensile strength of the lining and cover shall not be less than 1500 psi
(10,500 kpa ).
- Ultimate Elongation: 400 % minimum.
- Accelerated Aging Test: The tensile
strength and ultimate elongation of the vulcanized rubber compound which
has been
subjected to the action of oxygen at a pressure of 300 psi +/- 10 psi (2100kpa
+/- 70kpa) and temperature of 70 degrees centigrade +/-1 degree centigrade
(158 F +/- 18 F ) for a period of 96 hours shall be greater than 60% of the
original properties stated.
Abrasion Resistance:
Hose shall withstand more than 30,000 cycles on the taber abrasion machine
(H22 wheel ;1 kiloweight). Other standard abrasion test data can be supplied
on request, including UL, DIN, ETC..
Cold Resistance:
Hose shall have a capability of use down to - 36 F. Hose shall have no apparent
damage to cover, reinforcement or lining when subject to the following cold
bending test: A soft length of dry hose is to be firmly coiled and placed
in a cold box at - 36 F for a duration of 24 hours. Immediately after removal
of the hose from the box, hose should be uncoiled and laid out by one operator.
Following this procedure, the hose shall not leak nor show any damage to
the reinforcement when subjected to hydrostatic acceptance tests stated above.
Ozone Resistance:
Hose shall show no visible signs of cracking of the lining or cover when tested
in accordance with ASTM D1149-64 (R1970), ASTM D518 Procedure B, 100pphm/118
F/70 hours.
Chemical Resistance:
Exposure to seawater and contamination by most chemical substances, hydrocarbons,
oils, alkalis, acids and greases must have no effect on the short or long
term performance of the
hose. A chemical resistance chart is available and Ati will supply specific
chemical resistance data on request to the purchaser for unique applications.
Heat Resistance:
The hose when subjected to a static pressure of 100 psi ( 700 kpa ) shall be
capable of withstanding a surface temperature of 1200 F for a minimum of
two minutes without rupture or damage to the synthetic reinforcement. |